• Folks, if you've recently upgraded or renewed your annual club membership but it's still not active, please reach out to the BOD or a moderator. The PayPal system has a slight bug which it doesn't allow it to activate the account on it's own.

Search results

  1. S

    Birdsnest Question

    Found the culprits lastnite. Found about a dozen small nudibranchs on them. So, I fw dipped both and put them in QT. Something I put in the tank must of had eggs on them. Now for the waiting game........
  2. S

    Looking for Some Help with a Problem

    If its bubbles its probably nitrogen gas. It means the bacteria is doing its job. The tank is still young. Let it mature.
  3. S

    Looking for Some Help with a Problem

    So with all pumps off, even after 10-15 minutes, you still see bubbles rising in the tank? How old is the tank? How deep is the sand? Whats the ammonia, nitrite and nitrate levels? Might just be nitrogen gas.
  4. S

    Birdsnest Question

    gfo was changed after I noticed the shedding. SPS,LPS and softies all well spaced carbon gets replaced every week. GFO every 2-3 weeks. Weekly 20% water changes, well maybe every 2 weeks. ;) I'll try lowering them down a bit.
  5. S

    fragging palys?

    Faceshield, gloves and apron. Dont frag without them...........
  6. S

    Birdsnest Question

    I have two birdsnest colonies. One pink tip and one blue tip. Over the weekend, it appears both are shedding an outer layer. I havent really seen polyp extension either. But both still have color, albeit a little white. My other acros and monti's appear fine as well as everything else in the...
  7. S

    How hot did your tank get in this weather?

    81... 3 MH's, 4 96w PC's all in a hood with three 4" fans, fan over sump and AC at 73. No chiller.
  8. S

    micro bubbles

    Hmmmmmm..... You said its a AGA90RR. I assume it came with the return pipe and lineloc. If thats what you are using, check the top of the return stand pipe. They have a small anti siphon hole in them. Make sure while the pumps are running that this hole is submerged. I would also take a bright...
  9. S

    micro bubbles

    If a pump cavitates, it means its inlet or outlet is being restricted. You said you were using hose barbs. They are very restrictive. Their bore is much smaller than the pipe of the same size. What size pipe and how many bends are you using?
  10. S

    micro bubbles

    Do you see bubbles in the return section of the sump? If not then it sounds like the pump might be cavitating. Try putting a "t" in line and a valve and dump some water back into the sump. Just a side note, I find a over,under,over trap works much better.
  11. S

    acrylic

    Total Plastics in Maple Shade NJ. http://www.totalplastics.com/ You can also check some of the wood mills in your area. Sometimes they have old sheets in their racks that they will let go for a song and a dance.
  12. S

    Float Valve Plumbing Help

    No, an ASOV does NOT require a tank. The pressure build up from the closed float valve is enough. It does however require descent pressure from the water source. 40 psi if I am not mistaken. Also the membrane will continue to make waste water as long as the water source is available. So if you...
  13. S

    LED Lighting

    Rich, You actually cant compare any of those easily to one another. Lumen is a measure of perceived power of a light source. Lux is a measure of that perceived power of a light source that illuminates an area Par is a measure of that perceived power of a light source that illuminates an area...
  14. S

    Lighting Question

    The T6 bulb was made to fit a standard T12/T8 fixture but at the T5 efficiency. I haven't seen many T6 bulbs for this hobby. But if you are looking to get a new fixture. Just go with the T5.
  15. S

    just bought ro/di ebay

    Whats your water pressure going into the membrane? The higher end membranes are rated at 50psi, the lower cost units are rated at 65psi and higher. If your water pressure is low going in, the production will be slower.
  16. S

    TDS Meter reading

    0 from RO/DI. I run a Filmtec 75gpd membrane. I have rather clean well water that is typically <100ppm. If I see a creep after the DI, then I will check the incoming and out from the membrane. I know this membrane has a 98% rejection rate. So if I see less than that, then I will try a long (30...
Top